&Xn - Select Sync Transmit Clock Source
Command Line Format
AT [cmds] &X [suffix] [cmds] <CR>
Suffix Values
0 through 2
Factory Default
&X0
Stored by &Wn
yes
Displayed by &V
yes
Description
This command determines how the DTE transmit clock is generated while
the modem is in the synchronous mode.
&X0 - The modem generates the transmit clock and applies it to pin 15 (RS-232).
&X1 - The DTE generates the transmit clock on pin 24 (RS-232) and the modem
applies this clock to pin-15 (RS-232).
&X2 - The modem derives the transmit clock from the receive carrier signal
and applies it to pin-15 (RS-232).
DTE Interface Lines Affected
Clock leads (Pins 15, 17, & 24)
Cross Reference
Commands - &Qn
DTE signals - SCTE, SCT, SCR