S7 - Wait For Carrier
Description
The value in S7 sets the time limit to wait for the following events:
- Silent answer (@ dial modifier)
- Dial tone (W dial modifier)
- Carrier completion of handshaking timeout.
See also D command, @ dial modifier, W dial modifier,
plus Dialing Process, and Handshaking
Process.
Type
value (seconds)
Value range
1 to 255, Default value: 50
Stored by &Wn
yes
Displayed by &V
yes