S74 and S75 - Minimum Incoming Logical Channel Number (LCN)


Description
S74 and S75 combine to specify the lowest incoming Logical Channel Number the X.25 packet layer reports or accepts. The value used is formed by using S74 as the two high decimal digits and S75 as the two low decimal digits, or the value can be found by the formula S74*100+S75. If the resulting value is outside the range (0-4095), the value is assigned to the appropriate corresponding limit (e.g., if a value of 4099 is used, it is assigned to the upper limit value of 4095).

Type
value

Value range
S74 = 0 - Factory setting from a range of 0-40
S75 = 1 - Factory setting from a range of 0-99.

Stored by &Wn
yes

Displayed by &V
no

Click here to return to the Contents page.