S92 - MI/MIC Options
Description
S92 enables and selects or disables the mode indicate/mode indicate
common interface. The settings available for this register support various
combinations of edge- and level-detection in either originate or answer
mode with ring indicator (RI) pulse enabled or disabled. For information
about how the jack setting specified with the &J command interacts with
this register, see installation information for your modem.
Type
bit-mapped
Default value
0
Stored by &Wn
yes
Displayed by &V
no
Value Meanings
Bit Description
0 Enable MI/MIC operation
1 0 = triggered if contact closed
1 = triggered by contact closing
2 0 = originate mode
1 = answer mode
3 0 = RI enabled
1 = RI disabled
4 reserved
5 reserved
6 reserved
7 reserved
Note: This feature is not available to all modems. Refer to the feature
list in the installation information of your modem. Setting S92 to a value
other than its factory-set default of 0 automatically redefines the telephone
line jack setting specified by the &J command.
Click here to return to the Contents page.