S92 - MI/MIC Options


Description
S92 enables and selects or disables the mode indicate/mode indicate common interface. The settings available for this register support various combinations of edge- and level-detection in either originate or answer mode with ring indicator (RI) pulse enabled or disabled. For information about how the jack setting specified with the &J command interacts with this register, see installation information for your modem.

Type
bit-mapped

Default value
0

Stored by &Wn
yes

Displayed by &V
no

Value Meanings 
Bit    Description                                                                                             

0      Enable MI/MIC operation                                                                                 

1      0 = triggered if contact closed                                                                         

       1 = triggered by contact closing                                                                        

2      0 = originate mode                                                                                      

       1 = answer mode                                                                                         

3      0 = RI enabled                                                                                          

       1 = RI disabled                                                                                         

4      reserved                                                                                                

5      reserved                                                                                                

6      reserved                                                                                                

7      reserved                                                                                                
Note: This feature is not available to all modems. Refer to the feature list in the installation information of your modem. Setting S92 to a value other than its factory-set default of 0 automatically redefines the telephone line jack setting specified by the &J command.