Parameter 15 - Editing
Parameter 15 enables editing in the PAD online state. Parameters 16,
17, 18, and 19 define the available editing functions. If editing is enabled,
parameter 4 (forward timing) and National PAD Parameter 70 are ignored.
Parameter 15 supports the following values:
Values Description
0 Editing disabled (factory setting)
1 Editing enabled. Data forwarding is suspended until the editing
buffer is full, or until the character defined by parameter 3 is
received
Whenever more data is received than can be held by the editing buffer, one
full packet is forwarded. The remaining characters are placed in the beginning
of the editing buffer, and can still be edited.