National PAD Parameters 72 - Break Signal Timing
National PAD Parameters 72 controls whether break timing information
via National PAD Parameters 73 is sent with the indication of break PAD
message.
In most PADs, when a break signal is received from the terminal, the PAD
sends an X.25 interrupt packet, followed by an indication of break PAD message.
The remote PAD usually ignores the interrupt packet, and transmits a break
signal to the remote system when the indication of break PAD message is
received.
The duration of the break signal is normally fixed. National PAD Parameters
73 specifies the duration of the break signal transmitted by the PAD. If
National PAD Parameters 72 is set to value 0, the indication of break PAD
message is sent normally, and is compatible with all networks.
If National PAD Parameters 72 is set to value 1, break timing information
is sent along with the indication of break PAD message, by adding a parameter/value
field to the indication of break PAD message. This sets the remote PAD National
PAD Parameters 73 to a value that corresponds to the length of break as
timed by the local PAD, so the break signal transmitted by the local PAD
is very close to the length of the break signal received by the remote PAD.
Setting National PAD Parameters 72 to value 1 may confuse some networks,
and should be used only where the remote PAD supports National PAD Parameters
73.
National PAD Parameter 72 supports the following values:
Values Description
0 No break timing information sent with signal (factory
setting)
1 Break timing information is sent with the break signal
Click here to return to the Contents page.