PAD Para-
meter Values Description Default
1 0-126 PAD recall using a character 1 (DLE character)
2 0,1 Echo 1 (echo on)
3 0-127 Selection of data forwarding signal 126 (forward on control characters and
DEL)
4 0-255 Selection of idle timer delay 0 (no time-out)
5 0,1,2 Ancillary device control 1 (XON/XOFF enabled)
6 0,1,4,5 Control of PAD result codes 1 (standard PAD result codes enabled,
no prompt)
7 1,2,4,8,16 Response to break from terminal 2 (send reset packet)
8 0,1 Discard output 0 (normal delivery)
9 0-255 Padding after carriage return 0 (disabled)
10 0-255 Line folding 0 (disabled)
11 0,2-5, Terminal speed (speed of terminal indicated)
12-16
12 0,1 Flow control of PAD by terminal 1 (XON/XOFF disabled)
13 0-7 Linefeed insertion after CR 0 (disabled)
14 0-255 Linefeed padding 0 (disabled)
15 0,1 Editing 0 (disabled)
16 0-127 Character delete 127 (DEL character)
17 0-127 Line delete 24 (CAN, ^X)
18 0-127 Line display 18 (DC2, ^R)
19 0,1,2,8, Editing PAD result codes 1 (printing terminals)
32-126
20 0-255 Echo mask 0 (echo all characters)
21 0,2 Parity treatment 0 (disabled)
22 0-255 Page wait 0 (disabled)
70* 0,1 Streaming data forwarding 0 (disabled)
71* 0,5 Character format 0 (set by AT autobaud)
72* 0,1 Break signal timing 0 (disabled)
73* 0-255 Break signal duration 18 (180 ms.)
74* 0,1 Disable PAD parameter settings by remote 0 (parameters set by remote PAD)
PAD
100* 4-9 Default packet size 7 (128 bytes)
101* 2-7 Default window size 2 (2 outstanding packets)
102* 1-255 T21 call request response timer 20 (200 seconds)
103* 1-255 T22 reset request response timer 18 (180 seconds)
104* 1-255 T23 clear request response timer 18 (180 seconds)
105* 1-255 T26 interrupt response timer 18 (180 seconds)
106* 0-255 R22 reset request transmit again 1 transmit again
107* 0-255 R23 clear request transmit again 1 transmit again
108* 0-3 Channel allocation parameter 3 (normal channel allocation)
*National PAD Parameters